MRCOOL 60,000 BTU 5 Ton Hyper Heat Central Ducted Heat Pump Split System
MRCOOL 60,000 BTU 5 Ton Hyper Heat Central Ducted Heat Pump Split System - None / No Line Set is backordered and will ship as soon as it is back in stock.
Manufacturer's Warranty
Manufacturer's Warranty
What's In The Box?
What's In The Box?
Info & Guides
Info & Guides
MRCOOL 60,000 BTU 5 Ton Hyper Heat Central Ducted Heat Pump Split System - None / No Line Set is backordered and will ship as soon as it is back in stock.
Description
Description
Cold snaps are where many heat pumps fall short, and that is the gap the MRCOOL Hyper Heat central ducted system closes. Its DC inverter compressor varies its speed to match demand, so you get steady heat in deep winter and efficient cooling in summer. You finish the setup by choosing an auxiliary heat level and a line set length.
The system pairs mini-split efficiency with the airflow and coverage of a traditional HVAC system, which makes it a strong fit for whole homes and offices. Because the air handler is modular and has a self-diagnostics panel, your HVAC professional can service it faster. A removable filter also makes routine upkeep easier.
Key Features and Benefits of the MRCOOL 60,000 BTU 5 Ton Hyper Heat Central Ducted Heat Pump Split System
- Whole-Home Capacity: A 60,000 BTU, 5-ton rating with 54,000 BTU of cooling and 56,000 BTU of heating lets you condition spaces up to 2,500 square feet.
- Hyper Heat Range: Heating runs to 75 degrees Fahrenheit and cooling to 122, both working down to -22 degrees Fahrenheit outdoors, so you stay comfortable through extreme seasons.
- Energy Star Efficiency: SEER2 ratings up to 16.0 and an HSPF2 rating of 9.0 reduce your seasonal operating costs, while an EER2 of 10.0 keeps cooling efficient on peak days.
- Multi-Position Air Handler: The air handler installs upflow or downflow, or horizontally to the left or right, so it adapts to the way your ductwork is laid out.
- High Airflow: A maximum airflow of 2,648.6 CFM moves enough conditioned air to reach distant rooms on long duct runs throughout your home.
- Flexible Controls: A wired wall thermostat and a wireless remote with Follow Me sensing both come included, and third-party thermostats are also supported if you prefer your own.
- R-454B Refrigerant: This refrigerant has a lower global warming potential, so you reduce your environmental impact without giving up cooling output.
- Gold Fin Protection: Gold Fin technology on the outdoor condenser resists corrosion, which protects your coil in coastal or high-humidity climates.
- Certified Performance: Running on 208-230 volt power, the system carries AHRI certification and ETL listing, so your installer works from verified ratings and a recognized safety listing.
- Indoor Noise Level: Indoor sound peaks at 65 dB, which is worth knowing when you choose an air handler location near bedrooms or offices.
- Air Handler Size: The air handler measures 24.49 x 21.02 x 52.99-Inches (L x W x H) and weighs 162.92 pounds, so you can confirm closet or attic clearance.
- Condenser Size: The outdoor condenser measures 16.34 x 37.48 x 52.48-Inches (L x W x H) and weighs 242.95 pounds, which helps you plan the pad and placement outside.
Choose Your Auxiliary Heat and Line Set
You can configure this system on 2 axes: auxiliary heat runs from heat pump only up to a 20 kW electric resistance coil, and line set runs from none up to a 50-foot No-Vac Quick Connect kit.
- Heat Pump Only: The base configuration relies entirely on the inverter heat pump, which suits you if your winters are cold but rarely punishing for long stretches.
- With 10 kW Heater: This option adds an electric resistance coil to the base system, giving you a supplemental boost on the coldest mornings.
- With 15 kW Heater: This option steps up from the 10 kW coil to a larger backup heater, which gives you more reserve for larger homes in harsh winter regions.
- With 20 kW Heater: This top option builds on the 15 kW tier with a larger coil, giving you the most supplemental heat when temperatures stay near the system's -22 degrees Fahrenheit limit.
On the line set axis, the No Line Set option suits you if your installer is reusing existing copper or running a custom length, since the system supports runs up to 246 feet. The No-Vac Quick Connect line sets come in 15, 25, 35, or 50 feet and simplify the refrigerant connection. Every configuration includes an installation kit with stub pipes, copper nuts, a drain joint, and foam insulation.
Sylvane's Expert Take
If you heat a large home where winters drop well below zero, put this ducted heat pump on your shortlist. It performs best in homes near 2,500 square feet with sound ductwork, where the 5-ton capacity matches the load. Plan ahead: a licensed HVAC professional must install it.
The auxiliary heat choice matters most. Heat pump only covers milder winters, while the 15 kW or 20 kW heater suits the coldest regions. Whichever you pick, one system covers both summer cooling and deep-winter heat.
Specifications
Specifications
-
Energy Efficiency Ratio 2 (EER2)10
-
Mounting TypeFloor
-
Number of SpeedsVariable
-
Seasonal Energy Efficiency Ratio 2 (SEER2)16.0
-
Total Cooling Capacity (BTUs)54000
-
Total Heating Capacity (BTUs)56000
-
TypeCentral Split
-
Auxiliary HeatNoneNoneNoneNoneNone101010101515151520202020101520
-
CertificationsAHRI, ETL
-
ColorGray, White
-
Compressor TypeInverter
-
Heat ModeYes
-
Heating Seasonal Performance Factor 2 (HSPF2)9
-
Installation TypeProfessional Installation
-
Line Length OptionNo Line Set15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ftNo Line SetNo Line SetNo Line Set
-
Maximum Cubic Feet per Minute (CFM) (CFM)2648.6
-
Maximum Indoor Noise Level (dB)65
-
Maximum Operating Temperature - Cooling (degrees F)122
-
Maximum Operating Temperature - Heating (degrees F)75
-
Minimum Operating Temperature - Cooling (degrees F)-22
-
Minimum Operating Temperature - Heating (degrees F)-22
-
Number of Tons5
-
Refrigerant TypeR-454B
-
California Residents⚠ WARNING: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov.
-
Voltage (V)208-230
-
Included Line Length (ft.)No Line Set15253550152535501525355015253550No Line SetNo Line SetNo Line Set
-
Indoor Unit Depth (in.)24.49
-
Indoor Unit Height (in.)52.99
-
Indoor Unit Weight (lbs.)162.92
-
Indoor Unit Width (in.)21.02
-
Maximum Line Length (ft.)246
-
Outdoor Unit Depth (in.)16.34
-
Outdoor Unit Height (in.)52.48
-
Outdoor Unit Weight (lbs.)242.95
-
Outdoor Unit Width (in.)37.48
-
Additional FeaturesEnergy StarEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy StarEnergy StarEnergy Star
-
Manufacturer's Warranty10-Year Parts, Labor, and Compressor Warranty












