MRCOOL 30,000 BTU 2.5 Ton Hyper Heat Central Ducted Heat Pump Split System
MRCOOL 30,000 BTU 2.5 Ton Hyper Heat Central Ducted Heat Pump Split System - None / No Line Set is backordered and will ship as soon as it is back in stock.
Manufacturer's Warranty
Manufacturer's Warranty
What's In The Box?
What's In The Box?
Info & Guides
Info & Guides
MRCOOL 30,000 BTU 2.5 Ton Hyper Heat Central Ducted Heat Pump Split System - None / No Line Set is backordered and will ship as soon as it is back in stock.
Description
Description
Replacing an aging furnace and central AC doesn't have to mean redesigning your ductwork. The MRCOOL Hyper Heat central ducted split system connects to new or existing ducts and pairs a multi-position air handler with an inverter-driven outdoor condenser, so you get mini-split efficiency with whole-home reach. You can order it with or without auxiliary electric heat, and with or without a quick-connect line set.
The heat pump keeps heating when outdoor temperatures drop as low as -22 degrees Fahrenheit, which means you can rely on it through hard winters instead of falling back on a fossil-fuel furnace. Heating mode runs up to 75 degrees Fahrenheit outdoors. Cooling holds from -22 degrees Fahrenheit up to 122 degrees Fahrenheit, so the full 2.5 tons of capacity keeps working on the hottest afternoons.
Key Features and Benefits of the MRCOOL 30,000 BTU 2.5 Ton Hyper Heat Central Ducted Heat Pump Split System
- Inverter Compressor: A DC inverter compressor with variable-speed operation reaches up to 16.8 SEER2 and 11.7 EER2, so cooling your home costs less to run.
- Heating and Cooling: Produces 34,000 BTU of heating and 30,000 BTU of cooling, with a 10.0 HSPF2 seasonal heating efficiency rating, sized for ducted spaces up to 1,500 square feet.
- Multi-Position Air Handler: The floor-mounted air handler installs in 4 orientations (upflow, downflow, horizontal left, or horizontal right), so it fits the duct layout you already have.
- R-454B Refrigerant: Runs on this refrigerant, which has a much lower global warming potential than older formulas, so your system has a smaller environmental impact.
- Gold Fin Protection: Gold Fin technology on the outdoor condenser resists corrosion, which helps your system hold up in harsh environments year after year.
- Flexible Controls: Comes with a wired wall thermostat and a wireless remote with Follow Me, which adjusts output to the temperature sensed at the remote. Third-party thermostats are also compatible.
- Strong Airflow: Moves up to 3001.8 CFM to reach distant rooms, and peak indoor noise reaches 60.5 dB, a figure to weigh if the air handler sits near bedrooms.
- Long Line Runs: Supports refrigerant line runs up to 164 feet, which gives your installer more freedom in where the condenser sits.
- Certified Performance: Carries AHRI and ETL certification plus an Energy Star rating, confirming its efficiency performance.
- Simple Servicing: A self-diagnostics panel and modular air handler design help your technician find faults quickly, and the removable filter makes routine cleaning easy.
- Air Handler Size: It measures 21.02 x 21.02 x 49.02-Inches (L x W x H) and weighs 128.97 pounds, so confirm that your closet or basement has room.
- Outdoor Condenser Size: It runs on 208-230 volts and measures 37.24 x 16.14 x 31.89-Inches (L x W x H) and weighs 164.02 pounds, so match your power supply.
Choose Your Auxiliary Heat and Line Set
You can configure this heat pump system on 2 axes: auxiliary heat (None, 5 kW, 8 kW, 10 kW, or 15 kW) and line set length (No Line Set, 15 feet, 25 feet, 35 feet, or 50 feet).
If you choose None for auxiliary heat, you rely on the heat pump's 34,000 BTU output alone, which suits homes where winters rarely test the -22 degrees Fahrenheit heating limit. The 5 kW and 8 kW heat kits add electric resistance coils inside the air handler for backup on the coldest nights. Step up to the 10 kW or 15 kW kit when a larger or draftier home needs more reserve, since the supplemental coils supply up to 24,000 BTU of heat per hour.
With No Line Set, your installer provides the refrigerant piping and cuts it to the exact run. The 15-foot, 25-foot, 35-foot, and 50-foot configurations include the MRCOOL No-Vac Quick Connect Line Set along with the installation kit, so measure the distance between the air handler and condenser and pick the shortest length that covers it.
Sylvane's Expert Take
If you have ductwork and your winters regularly drop well below freezing, this Hyper Heat system belongs on your list. It works best in homes up to 1,500 square feet that are replacing a furnace and central AC together. A licensed HVAC professional must install it, so get a contractor lined up early.
The inverter compressor and the -22 degrees Fahrenheit heating rating matter most. Add a heat kit only if your area often hits that limit. For a cold-climate home with ducts, this heat pump will carry you through winter.
Specifications
Specifications
-
Energy Efficiency Ratio 2 (EER2)11.7
-
Mounting TypeFloor
-
Number of SpeedsVariable
-
Seasonal Energy Efficiency Ratio 2 (SEER2)16.8
-
Total Cooling Capacity (BTUs)30000
-
Total Heating Capacity (BTUs)34000
-
TypeCentral Split
-
Auxiliary HeatNoneNoneNoneNoneNone555588881010101015151515581015
-
CertificationsAHRI, ETL
-
ColorGray, White
-
Compressor TypeInverter
-
Heat ModeYes
-
Heating Seasonal Performance Factor 2 (HSPF2)10
-
Installation TypeProfessional Installation
-
Line Length OptionNo Line Set15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ftNo Line SetNo Line SetNo Line SetNo Line Set
-
Maximum Cubic Feet per Minute (CFM) (CFM)3001.8
-
Maximum Indoor Noise Level (dB)60.5
-
Maximum Operating Temperature - Cooling (degrees F)122
-
Maximum Operating Temperature - Heating (degrees F)75
-
Minimum Operating Temperature - Cooling (degrees F)-22
-
Minimum Operating Temperature - Heating (degrees F)-22
-
Number of Tons2.5
-
Refrigerant TypeR-454B
-
California Residents⚠ WARNING: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov.
-
Voltage (V)208-230
-
Included Line Length (ft.)No Line Set1525355015253550152535501525355015253550No Line SetNo Line SetNo Line SetNo Line Set
-
Indoor Unit Depth (in.)21.02
-
Indoor Unit Height (in.)49.02
-
Indoor Unit Weight (lbs.)128.97
-
Indoor Unit Width (in.)21.02
-
Maximum Line Length (ft.)164
-
Outdoor Unit Depth (in.)16.14
-
Outdoor Unit Height (in.)31.89
-
Outdoor Unit Weight (lbs.)164.02
-
Outdoor Unit Width (in.)37.24
-
Additional FeaturesEnergy StarEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy StarEnergy StarEnergy StarEnergy Star
-
Manufacturer's Warranty10-Year Parts, Labor, and Compressor Warranty












