Description
Description
When a server room starts overheating or a production floor loses its HVAC, the KwiKool 120,000 BTU 10-Ton Portable Air Conditioners give you the most cooling power in the KwiKool line. These commercial-only air conditioners vent through a drop ceiling, so you can place them where the heat builds up instead of next to a window. The line comes in 2 voltage configurations to match your facility's 3-phase service.
Continuous duty is the biggest advantage. An internal pump sends condensate to a drain, so cooling keeps going overnight and through weekends without anyone emptying water. For a shorter job, the external tank collects water instead. Facilities like hospitals and offices use this 2-way setup to cover both emergency and planned cooling.
Key Features and Benefits of the KwiKool 120,000 BTU 10-Ton Portable Air Conditioners
- 120,000 BTU Cooling: A 10-ton cooling capacity handles spaces up to 4,000 square feet, so a single machine can cool a full warehouse bay or server hall.
- High-Volume Airflow: Direct-drive fans move up to 3,800 CFM through the evaporator and 5,000 CFM across the condenser, pushing cold air across large open floors.
- Internal Condensate Pump: The built-in pump lifts water to a drain up to 150 feet away, so you can run cooling 24 hours a day without emptying anything.
- 5-Gallon Tank: For temporary jobs, the external tank holds up to 5 gallons, then sounds an alarm and shuts off when full to prevent overflow.
- Wide Operating Range: Charged with R-454B refrigerant, these air conditioners run in ambient temperatures from 60 to 110 degrees F, so they keep cooling in hot plant conditions.
- Digital Thermostat: Electronic controls let you set temperatures from 60 to 99 degrees F and switch between cool and fan-only modes.
- Pressure Protection: High- and low-pressure switches shut the system down if ambient heat goes past 110 degrees F or condenser pressure drops, protecting the compressor during long runs.
- Auto-Restart: After a power outage, the air conditioner comes back on with your previous settings, so server rooms stay cooled with nobody on site to reset it.
- Dual-Hose Venting: A dual-hose design with 20-inch vent connections supports duct runs up to 65 feet, so you can exhaust heat through a drop ceiling away from the cooled area.
- Rugged Cabinet: The galvanized, hammercoat-finished cabinet measures 58 x 33 x 69-Inches (L x W x H) and rolls on casters, so you can move it around your floor.
- Safety Listings: ETL, CSA, and UL listings give your facility managers and inspectors third-party proof of safe operation.
Choose Your Voltage
You can pick between the 208-230 volt and 440-460 volt models depending on the 3-phase power your building supplies.
- 208-230 Volt Model KIB12023: The KIB12023 draws a maximum of 52.9 amps on an 80-amp breaker and weighs 986 pounds, a good match for facilities wired for standard commercial 3-phase power.
- 440-460 Volt Model KIB12043: The KIB12043 draws a maximum of only 26.2 amps on a 40-amp breaker and weighs 1,000 pounds, a good match for plants with high-voltage 3-phase distribution.
Note: Both models are hardwired and use 3-phase motors, so confirm your facility's supply matches before installation.
Sylvane's Expert Take
If you manage a server room or hospital wing that can't afford cooling downtime, plan around this KwiKool line. It works best in large rooms with a drop ceiling, where the ducted exhaust can reach the plenum. Expect close to 1,000 pounds of machine, so plan where it will sit before it arrives.
The condensate pump and auto-restart matter most, because together they keep cooling running unattended. Choosing a model only means matching your building's voltage, since cooling performance is the same on both.
Specifications
Specifications
-
ASHRAE Cooling Power (BTUs)120000
-
Internal Condensate PumpYes
-
ApplicationCommercial/Industrial
-
CertificationsETL
-
ColorBlue
-
ControlsElectronic
-
Heat ModeNo
-
Hose TypeDual Hose
-
Maximum Cubic Feet per Minute (CFM) (CFM)3800.0
-
Maximum Noise Level (dB)125
-
Maximum Operating Temperature (degrees F)110
-
Maximum Thermostat Setting (degrees F)99
-
Minimum Operating Temperature (degrees F)60
-
Minimum Thermostat Setting (degrees F)60
-
Recommended Coverage Area (sq. ft.)4000
-
Recommended ForServer Room & Precise Indoor Applications
-
Refrigerant TypeR-454B
-
Self-EvaporationPartial
-
California Residents⚠ WARNING: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov.
-
Maximum Amperage (Amps)26.252.9
-
Maximum Wattage (W)15
-
Plug Face TypeHardwired
-
Power Cord Length (ft.)10
-
Recommended Breaker Size (Amps)4080
-
Voltage (V)440-460208-230
-
Depth (in.)58.0
-
Height (in.)69.0
-
Vent Hose Diameter (in.)20
-
Vent Hose Length (ft.)Up to 65
-
Weight (lbs.)1000986
-
Width (in.)33.0
-
Additional FeaturesFull Bucket Indicator/Auto Shutoff, Adjustable Louvers, Drain Hose Capable, Fan-Only Mode, Auto-Restart, Applicable for Indoor Growing, Casters, Internal Condensate Pump
-
Manufacturer's Warranty1-Year Limited Warranty