Friedrich 10,000 BTU ZoneAire Premier PTAC with Electric Heat
Friedrich 10,000 BTU ZoneAire Premier PTAC with Electric Heat - 208-230V is backordered and will ship as soon as it is back in stock.
Manufacturer's Warranty
Manufacturer's Warranty
What's In The Box?
What's In The Box?
Info & Guides
Info & Guides
Friedrich 10,000 BTU ZoneAire Premier PTAC with Electric Heat - 208-230V is backordered and will ship as soon as it is back in stock.
Description
Description
A guest room can sit empty for days, and the Friedrich 10,000 BTU ZoneAire Premier PTAC with Electric Heat keeps it ready the whole time. Room freeze protection turns on the heat if an unoccupied room drops to 40 degrees F, so no guest walks into a cold room. A modular layout gives maintenance quick access to components, and the permanent filter rinses clean with warm water and mild dish soap.
Key Features and Benefits of the Friedrich 10,000 BTU ZoneAire Premier PTAC with Electric Heat
- 10,000 BTU Cooling: A 0.85 sensible heat ratio means most of its capacity goes to lowering air temperature in rooms up to 400 square feet.
- Electric Coil Heat: Delivers 8,300 to 17,000 BTU (up to 5,000 watts) so rooms stay warm on cold nights, and a 20-amp, 3-kW heater cord comes standard.
- High EER Rating: A 12.5 EER means more cooling for each watt it uses, which helps you keep energy costs down across a building full of rooms.
- R-32 Refrigerant: Uses a refrigerant with low global warming potential, so your property cuts its environmental impact without losing cooling output.
- Wide Operating Range: Operates in temperatures from 64 to 115 degrees F, so you can count on steady cooling through the hottest weeks of summer.
- 2-Motor Design: Separate indoor and outdoor motors let the indoor fan run slower, which keeps sound to a maximum of 50 dB and helps guests sleep.
- Even Airflow: A tangential blower wheel with nearly 5 times the surface area of a typical PTAC fan moves up to 330 CFM, so air spreads evenly across the room.
- Built-In Dehumidification: Removes up to 2.11 pints of moisture per hour, so your rooms feel less clammy during humid stretches.
- Control Options: Electronic digital controls let you set temperature, mode, and fan speed, while desk control readiness connects to your hotel energy management system for remote staff control.
- Corrosion-Resistant Build: Stainless steel parts and a white powder-coated finish resist rust and corrosion, which helps the PTAC hold up through years of seasonal exposure.
- cETLus Certified: Carries cETLus certification, confirming the PTAC has been tested to safety standards for the United States and Canada.
- Size and Weight: Measures 42 x 13.75 x 16-Inches (L x W x H) and weighs 110.3 pounds, so check your wall opening and lifting plan before installation day.
Choose Your Voltage
Matching the PTAC to your building's electrical service starts with picking between the 208-230V and 265V configurations.
- 208-230V Model PDE09K3SGR3: This model runs on 208 to 230 volts through a 6-20P plug and a cord 6 feet long, reaching outlets farther away, while drawing 3.9 amps and 810 watts when cooling and up to 21.8 amps in heat mode.
- 265V Model PDE09R3SGR3: This model runs on 260 to 280 volts through a 7-20P plug and a cord 2.3 feet long that must sit close to the outlet, drawing 3.2 amps and 800 watts when cooling and up to 18.9 amps in heat mode, a lighter load for buildings wired for 265-volt service.
Note: The 208-230V model draws up to 21.8 amps in heat mode, so confirm your circuit can carry that load.
Sylvane's Expert Take
If you manage a hotel or dorm with rooms up to 400 square feet, this PTAC line works best where guests expect quiet nights and staff want central oversight. Picking a voltage comes down to the wiring already behind the wall, since both models share identical cooling and heating output and the same 50-dB ceiling. Desk control readiness is the feature that matters most, because it lets you rein in energy use in vacant rooms. Add freeze protection, and the ZoneAire Premier pays off in any property where occupancy rises and falls with the seasons.
Specifications
Specifications
-
Energy Efficiency Ratio (EER)12.5
-
Number of Speeds2
-
CertificationscETLus
-
ColorWhite
-
ControlsElectronic
-
Electric Heat BTU's (BTUs)8,300-17,000
-
Heater TypeElectric Coil
-
Maximum Cubic Feet per Minute (CFM) (CFM)330.0
-
Maximum Noise Level (dB)50
-
Maximum Operating Temperature (degrees F)115
-
Minimum Operating Temperature (degrees F)64
-
Moisture Removal per Hour (pints)2.11
-
Recommended Coverage Area (sq. ft.)400
-
Refrigerant TypeR-32
-
Sensible Heat Ratio.85
-
California Residents⚠ WARNING: Cancer and Reproductive Harm. For more information go to www.p65warnings.ca.gov.
-
Branch Circuit Fuse (amps)20
-
Electric Heat Max Amps (Amps)21.818.9
-
Electric Heat Max Wattage (W)5000
-
Maximum Cooling Amperage (Amps)3.93.2
-
Maximum Cooling Wattage (W)810800
-
Plug Face Type6-20P7-20P
-
Power Cord Length (ft.)62.3
-
Voltage (V)208-230260-280
-
Cut Out Dimensions (H x W) (in.)42.25x16.25
-
Depth (in.)13.75
-
Height (in.)16.0
-
Weight (lbs.)110.3
-
Width (in.)42.0
-
Additional FeaturesAdjustable Louvers, Fan-Only Mode
-
Manufacturer's Warranty
- 2-Year Limited Warranty on Parts and Labor
- 5-Year Limited Warranty on Sealed Refrigeration System





