Description
Description
Swapping out a tired furnace and central air conditioner doesn't have to mean redoing your ducts. The MRCOOL Hyper Heat Central Ducted Heat Pump Split System connects to new or existing ductwork, giving you the inverter efficiency of a mini-split with the whole-house reach of traditional HVAC.
Plan the space before installation day. The floor-mounted air handler measures 21.02 x 21.02 x 49.02-Inches (L x W x H) and weighs 129.41 pounds, while the outdoor condenser measures 38.58 x 16.34 x 38.39-Inches (L x W x H) and weighs 204.15 pounds, so plan for floor space and service access around the air handler and condenser. A licensed HVAC professional must install the system.
Key Features and Benefits of the MRCOOL 36,000 BTU 3 Ton Hyper Heat Central Ducted Heat Pump Split System
- Cold-Climate Heating: Heating runs in outdoor temperatures from -22 to 75 degrees F, and cooling runs from -22 to 122 degrees F, so you stay comfortable year-round.
- Matched Capacity: The system delivers 36,000 BTU of cooling and 37,000 BTU of heating, enough to condition ducted spaces up to 1,500 square feet.
- Efficiency Ratings: A 17.4 SEER2 and 10.2 HSPF2 rating help lower your seasonal energy costs, with an 11.7 EER2 for efficient cooling on the hottest days.
- Inverter Compressor: A DC inverter compressor with variable speed adjusts output to match demand, holding steadier temperatures than basic on/off systems.
- Multi-Position Air Handler: The air handler installs in upflow or downflow orientation, or horizontally to the left or right, so it adapts to however your existing ductwork is laid out.
- Strong Airflow: A maximum airflow of 3,001.8 CFM pushes conditioned air through your duct runs so distant rooms get their share.
- R-454B Refrigerant: This refrigerant lowers Global Warming Potential and environmental impact while keeping cooling powerful and efficient.
- Gold Fin Coil: Gold Fin technology helps the outdoor condenser resist corrosion, so it holds up through harsh weather season after season.
- Dual Controls Included: A wired wall thermostat and wireless remote both ship included, and third-party thermostat compatibility lets you keep the controller you already use.
- Follow Me Function: The wireless remote senses the temperature where you are and tells the system to adjust output for that spot.
- Long Line Runs: A maximum line length of 246 feet gives your installer flexibility to place the condenser well away from the air handler.
- Certified and Rated: AHRI, ETL, and Energy Star recognition verify performance and safety, and the system requires a 208-230 volt power supply.
Choose Your Auxiliary Heat and Line Set Length
Choose auxiliary heat from None, 5 kW, 8 kW, 10 kW, 15 kW, or 20 kW, and pair it with a line set of No Line Set, 15 feet, 25 feet, 35 feet, or 50 feet.
- No Auxiliary Heat: Heating comes entirely from the inverter heat pump, with no supplemental electric heater added.
- 5 kW Auxiliary Heat: This electric resistance coil heater is the first step up from no backup heat.
- 8 kW Auxiliary Heat: Stepping up from the 5 kW heater, this option adds an electric resistance coil for more backup heat.
- 10 kW Auxiliary Heat: This electric resistance coil heater provides greater supplemental output than the 8 kW option.
- 15 kW Auxiliary Heat: This electric resistance coil heater supplies more supplemental heat than the 10 kW option.
- 20 kW Auxiliary Heat: This is the top option in the lineup, and it delivers the most electric resistance coil supplemental heat.
Line set length is a separate choice from heat. Choose No Line Set when your installer is supplying the refrigerant piping. The 15-foot and 25-foot options suit installs where the condenser sits close to the air handler, while 35-foot and 50-foot lengths reach longer runs. All four lengths from 15 to 50 feet use the No-Vac Quick Connect design, which works with the included installation kit to make professional installation easier.
Sylvane's Expert Take
If you're replacing an aging furnace and central air conditioner in a cold-climate home with existing ducts, this Hyper Heat line fits the job well. Variable-speed operation, with indoor sound peaking at 49 dB, makes it a good fit for homes where steady comfort matters most. Match auxiliary heat to your winter design temperature, and let your installer measure the run before you choose a line set. Size those 2 choices correctly and this heat pump can carry your home through every season.
Specifications
Specifications
-
Energy Efficiency Ratio 2 (EER2)11.7
-
Mounting TypeFloor
-
Number of SpeedsVariable
-
Seasonal Energy Efficiency Ratio 2 (SEER2)17.4
-
Total Cooling Capacity (BTUs)36000
-
Total Heating Capacity (BTUs)37000
-
TypeCentral Split
-
Auxiliary HeatNoneNoneNoneNoneNone5555888810101010151515152020202058101520
-
CertificationsAHRI, ETL
-
ColorGray, White
-
Compressor TypeInverter
-
Heat ModeYes
-
Heating Seasonal Performance Factor 2 (HSPF2)10.2
-
Installation TypeProfessional Installation
-
Line Length OptionNo Line Set15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ft15 ft25 ft35 ft50 ftNo Line SetNo Line SetNo Line SetNo Line SetNo Line Set
-
Maximum Cubic Feet per Minute (CFM) (CFM)3001.8
-
Maximum Indoor Noise Level (dB)49
-
Maximum Operating Temperature - Cooling (degrees F)122
-
Maximum Operating Temperature - Heating (degrees F)75
-
Minimum Operating Temperature - Cooling (degrees F)-22
-
Minimum Operating Temperature - Heating (degrees F)-22
-
Number of Tons3
-
Refrigerant TypeR-454B
-
California Residents⚠ WARNING: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov.
-
Voltage (V)208-230
-
Included Line Length (ft.)No Line Set152535501525355015253550152535501525355015253550No Line SetNo Line SetNo Line SetNo Line SetNo Line Set
-
Indoor Unit Depth (in.)21.02
-
Indoor Unit Height (in.)49.02
-
Indoor Unit Weight (lbs.)129.41
-
Indoor Unit Width (in.)21.02
-
Maximum Line Length (ft.)246
-
Outdoor Unit Depth (in.)16.34
-
Outdoor Unit Height (in.)38.39
-
Outdoor Unit Weight (lbs.)204.15
-
Outdoor Unit Width (in.)38.58
-
Additional FeaturesEnergy StarEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy Star, Line Set IncludedEnergy StarEnergy StarEnergy StarEnergy StarEnergy Star
-
Manufacturer's Warranty10-Year Parts, Labor, and Compressor Warranty