Friedrich 7,200 BTU ZoneAire Select PTAC w/ Heat Pump

SKU: fr9710  |  Model: PZH07K3SC
Sale price $1,04900 Regular price $1,19900

Have a question or need a quote? Ask Our Experts

Live Chat | 1 (800) 934-9194 | Email

Manufacturer's Warranty

2-Year Limited Parts and Labor Warranty, 5-Year Limited Sealed Refrigeration System Warranty

What's In The Box?

  • Friedrich ZoneAire Select PTAC with Heat Pump
  • Owner's Manual

Info & Guides

Description

Rattling compressors and drafty heat cause many of the comfort complaints in hotels and dorms. The Friedrich 7,200 BTU ZoneAire Select PTAC w/ Heat Pump deals with both. Dual fan motors and a vibration-isolated rotary compressor keep sound down, while the heat pump covers most of your heating needs for less energy.

Heating runs in stages. The heat pump moves warmth in from outdoors instead of generating it. When temperatures fall below 40 degrees F, the built-in electric heater takes over. Instant Heat Mode uses that heater to bring a cold room up to temperature quickly, then hands off to the heat pump to hold it there.

Key Features and Benefits of the Friedrich 7,200 BTU ZoneAire Select PTAC w/ Heat Pump

  • Cooling Capacity: Delivers 7,200 BTU of cooling and 350 CFM of airflow, sized for guest rooms and dorms up to 300 square feet.
  • Heat Pump Heating: Provides 6,000 BTU of heat by transferring warmth from outdoors, so you use less energy than resistance heating alone.
  • Backup Electric Heat: An included 3,650-watt heater adds 12,000 BTU of heat when it is too cold outside for the heat pump to keep up.
  • Efficiency Rating: An Energy Efficiency Ratio of 12 and a maximum cooling draw of 590 watts help keep your operating costs down across many rooms.
  • R-32 Refrigerant: Uses a low global warming potential refrigerant and operates from 53 to 114 degrees F.
  • Quiet Operation: Dual permanently lubricated fan motors and an isolated rotary compressor cap sound at 53 dB, so your guests can sleep undisturbed.
  • Electronic Controls: Button controls with an LED display let you adjust temperature and fan speed (high, low, or auto) right at the PTAC.
  • Thermostat Ready: A pop-out wiring module connects the PTAC to a remote wall thermostat or energy management system, so you can control several rooms centrally.
  • Freeze Protection: In auto heat, the electric heater starts automatically if a room drops below 50 degrees F, protecting the heat pump in empty rooms.
  • Dehumidification: Removes up to 0.69 pints of moisture per hour, so rooms feel less clammy during humid weather.
  • Diamonblue Coil Coating: Diamonblue Advanced corrosion protection on indoor and outdoor coils, plus aluminum endplates, helps the PTAC hold up in harsh outdoor environments.
  • cETLus Listed: Carries cETLus certification, confirming the PTAC meets US and Canadian electrical safety standards.

Check Your Wall Opening and Circuit Before Installing

The PTAC measures 42 x 21.5 x 16-Inches (L x W x H) and weighs 93 pounds. Its 42-inch width is the industry standard, which makes it simple to swap in where an older PTAC is coming out. It runs on 208-230 volts through a 6-20P plug on a 6-foot cord, so you need a matching outlet close to the wall opening. Electric heat draws up to 15.9 amps, which is why it calls for a 20-amp branch circuit.

Sylvane's Expert Take

If you run a hotel or dorm with rooms up to 300 square feet, this PTAC works best in mild-winter climates, where the heat pump can carry most of the heating. Automatic freeze protection is the standout detail, because it protects empty rooms between bookings without anyone on staff stepping in. Focus on the 53 dB noise ceiling and the pop-out thermostat module, since the first keeps guest complaints down and the second lets you move to central control. For quiet heating and cooling in compact rooms, this PTAC is hard to beat.

Specifications

    Key Specifications

    • Energy Efficiency Ratio (EER)
      12.0
    • Number of Speeds
      2

    General

    • Certifications
      cETLus
    • Color
      White
    • Controls
      Electronic
    • Electric Heat BTU's (BTUs)
      12000
    • Heater Type
      Heat Pump
    • Heating BTUs (BTUs)
      6000
    • Maximum Cubic Feet per Minute (CFM) (CFM)
      350.0
    • Maximum Noise Level (dB)
      53
    • Maximum Operating Temperature (degrees F)
      114
    • Minimum Operating Temperature (degrees F)
      53
    • Moisture Removal per Hour (pints)
      0.69
    • Recommended Coverage Area (sq. ft.)
      300
    • Refrigerant Type
      R-32
    • Sensible Heat Ratio
      0.89
    • California Residents
      ⚠ WARNING: Cancer and Reproductive Harm. For more information go to www.p65warnings.ca.gov.

    Power

    • Branch Circuit Fuse (amps)
      20
    • Electric Heat Max Amps (Amps)
      15.9
    • Electric Heat Max Wattage (W)
      3650
    • Maximum Cooling Amperage (Amps)
      2.8
    • Maximum Cooling Wattage (W)
      590
    • Maximum Heating Amperage (Amps)
      2.4
    • Maximum Heating Wattage (W)
      500
    • Plug Face Type
      6-20P
    • Power Cord Length (ft.)
      6
    • Voltage (V)
      208-230

    Dimensions

    • Cut Out Dimensions (H x W) (in.)
      42.25x16.25
    • Depth (in.)
      21.5
    • Height (in.)
      16.0
    • Weight (lbs.)
      93
    • Width (in.)
      42.0

    Additional Features

    • Additional Features
      Adjustable Louvers, Fan-Only Mode

    Warranty

    • Manufacturer's Warranty
      2-Year Limited Parts and Labor Warranty, 5-Year Limited Sealed Refrigeration System Warranty