Description
Description
Modern building codes call for more outdoor air in commercial spaces, and every cubic foot you bring in has to be heated, cooled, or dried. The S&P TRCeN Series Commercial Energy Recovery Ventilator handles that load with an air-to-air recovery core. The core pre-conditions incoming air using the outgoing stream and keeps the 2 airflows separate. You can pick a single-direction or a V-type dual-direction airflow configuration.
The cabinet is laid out for service. Access doors open to the blowers, core, and filters, and differential pressure ports in the core let you take pressure readings to monitor how the system is running. You can set it on a concrete floor using the factory-provided leveling legs or attach it to a ceiling or structural support.
Key Features and Benefits of the S&P TRCeN Series Commercial Energy Recovery Ventilator
- Airflow Range: Delivers 166 to 488 CFM of fresh air exchange, so you can match ventilation to the occupancy of your commercial space.
- Twin EC Motors: Dual direct-drive 170-watt electronically commutated motorized impellers with independent electronic blower control let you balance supply and exhaust with high fan efficacy.
- AHRI-Certified Core: The L85-G5 recovery core is AHRI 1060 certified, giving you third-party verified energy recovery performance to put on your mechanical schedule.
- Frost Resistance: The resin core's moisture transfer stops moisture and frost build-up down to -10 degrees F and 40 percent RH, and you won't need a condensate pan or drain.
- MERV 8 Filtration: Twin MERV 8 filters measuring 14 x 20 x 2-Inches (L x W x H) clean both outside air and room air before it circulates.
- Insulated Steel Cabinet: A fully insulated 20-gauge galvanized steel cabinet protects the internal components and limits heat transfer through the casing.
- Electrical Requirements: The hardwired 208-230 volt single-phase supply draws 1.16 FLA per motor, with 2.6 minimum circuit amps and 15 amps MOPD, so your electrician can size the circuit quickly.
- Built-In Disconnect: A non-fused disconnect and a 24 VAC transformer relay package come built in, which makes power and control wiring on site simpler.
- Duct Connections: Square 12 x 12-inch receiving flanges connect to new or existing ductwork, which suits both retrofits and new construction.
- Certifications: Carries cETLus listing and Ecowatt certification, and meets the 2009 domestic-content standard plus BABA under IIJA (2022) for publicly funded projects.
- Size and Weight: It measures 50.25 x 40.25 x 17.5-Inches (L x W x H) and weighs 148 pounds, so you can plan the floor space or ceiling supports ahead of time.
Same-Side vs. Opposite-Side Airflow: Choose Your Configuration
The TRCeN Series comes in a Single Direction Airflow configuration and a V-Type Dual Direction Airflow configuration, and the right one depends on where your return air and outside air ducts reach the ventilator.
- Single Direction Airflow (TRCeN500): Return air and outside air both enter on the same side of the cabinet, which suits installations where both duct runs come from one direction.
- V-Type Dual Direction Airflow (TRCeN500V): Return air and outside air enter on opposite sides of the cabinet, so each duct can run straight to its own side when the runs come from opposing directions.
Sylvane's Expert Take
If you're specifying ventilation for a commercial space in a cold climate, this ERV deserves a close look. The resin core is the feature to note: it resists frost down to -10 degrees F and needs no condensate pan or drain, so you can place it where plumbing would be difficult. Choose your configuration based on duct layout, not performance, because both versions perform the same. On BABA-funded projects, it meets the domestic-content requirements as shipped.
Specifications
Specifications
-
Minimum Cubic Feet per Minute (CFM) (CFM)166.0
-
Mounting TypeFloor, Ceiling
-
Port LocationSide
-
TypeERV-Air Supply Fan
-
ApplicationCommercial/Industrial
-
CertificationsAHRI, cETLus
-
ColorGray
-
ControlsElectronic
-
Maximum Cubic Feet per Minute (CFM) (CFM)488.0
-
California Residents⚠ WARNING: This product can expose you to chemicals including formaldehyde, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov.
-
Maximum Amperage (Amps)1.16
-
Power SupplyHardwired
-
Voltage (V)208-240
-
Watts (W)170
-
Depth (in.)50.25
-
Duct Diameter (in.)6.0
-
Height (in.)17.5
-
Weight (lbs.)148
-
Width (in.)40.25
-
Manufacturer's Warranty10-Year Core Warranty, 2-Year Unit Warranty